Simulation Hub K9 Simulators K9 Diesel
TacMed Solutions

K9 Diesel

Advanced Canine Medical Trainer
DoD Co-Developed
Remote Controlled
28+ Features
Real-Time Sensors
Platform Overview

The most advanced canine medical trainer available — designed in partnership with the US Department of Defense.

K9 Diesel is a full-body simulator for Operational Canine First Responders, Military Working Dog (MWD) handlers, Veterinarians and Veterinary Technicians. A state-of-the-art skills trainer that simulates active breathing, audio cues and over 28 different features and medical intervention sites.

Each training site is designed to replicate the look, feel and function of actual medical procedures. Interchangeable limbs and injuries provide greater flexibility to vary wound patterns. K9 Diesel allows learners to perform a wide range of critical life-saving tasks with an incredibly realistic experience.

Primary User
Operational Canine First Responders
Primary User
Military Working Dog (MWD) Handlers
Primary User
Veterinarians
Primary User
Veterinary Technicians
Why K9 Diesel

Canine
Fidelity.
Tactical Realism.

K9 Diesel is operated by a long-range wireless remote controller (RC) that includes real-time data to monitor medical interventions remotely. LED indicators and LCD readouts immediately display critical vital and intervention data — giving instructors instant feedback on the effectiveness of student interventions.

Push-button controls allow live modification of pulse rate, pulse strength, breathing, bleeding and sounds — including five distinct audio modes: growling, barking, whimper, stertor and stridor.

Interchangeable front and rear limbs expand wound pattern capability — combined with intestinal evisceration, GDV (Gastric Dilatation-Volvulus), junctional wounds and lacerated paw to present the full range of canine trauma presentations encountered in operational and clinical environments.

Designed in Partnership With the US Department of Defense

K9 Diesel was developed in direct partnership with the DoD — ensuring training fidelity, intervention site accuracy and operational relevance are built into the platform from the ground up, not retrofitted.

5-Mode Canine Audio

Growling, barking, whimper, stertor and stridor — remotely selectable audio that reflects canine respiratory status and distress levels during training scenarios.

Hemostatic Axillary Wounds

Bilateral pressure-sensitive axillary wounds with sensor feedback — when correct wound-packing pressure is applied, bleeding occludes and the RC signals success. Insufficient pressure keeps the wound bleeding.

Interchangeable Limbs & Injuries

Interchangeable front and rear limbs vary wound patterns across training sessions — preventing scenario familiarity and maintaining training fidelity over repeated use.

Real-Time Intervention Monitoring

LED indicators and LCD readouts display critical vital and intervention data in real time — instructors see immediate feedback on CPR quality, needle decompression and IV/IO placement.

Co-Developed With
US Dept. of Defense
K9 Diesel — Advanced Canine Medical Trainer
Training Elements

28+ Features
& Intervention
Sites

K9 Diesel's 28+ features and intervention sites are organised across six clinical domains. Every site is designed to replicate the look, feel and function of actual canine medical procedures — from basic airway management through to GDV, evisceration and IO infusion.

01
Airway & Breathing
7 features
Simulated nasal airway — CPR forced air capability
Simulated oral airway with teeth and tongue
Intubation — accepts 10–12mm ET tubes
Responsive airway — chest inflation feedback on ventilation
Tracheostomy site with replaceable trachea
Adjustable breathing rate — 10–120 bpm via RC
Moveable jaw
02
Circulation & Pulses
5 features
Bilateral femoral pulses — palpable
Pulse rate — adjustable 50–170 bpm via RC
Pulse strength — weak, medium or strong via RC
CPR site — chest compressions perpendicular to elbow bend
Dead or Alive — instructor-set patient state
03
Vascular Access
3 features
Bilateral cephalic IV with flash cue
Bilateral humeral intraosseous (I/O) — infusible
Bilateral tibial intraosseous (I/O) — infusible
04
Thoracic & Trauma
6 features
Bilateral needle decompression with air release
Tension pneumothorax — RC-controlled state
Bilateral hemostatic axillary wounds — pressure sensor
Moveable simulated GSW for chest seal training
Intestinal evisceration — removable
GDV (Gastric Dilatation-Volvulus) — RC-activated
05
Wound Patterns & Limbs
5 features
Removable, interchangeable front and rear limbs
Front and rear amputations — arterial bleeding, pressure-responsive
Front and rear leg fractures
Lacerated front paw (right) — bandage and suture training
Removable facial wound — optional, drives tracheostomy
06
Patient ID & Scenario Control
4 features
5-mode audio — barking, growling, whimper, stertor, stridor
Programmable scenarios — set and toggle via RC
Ear tattoo — identification marker
Microchip-compatible — pocket between shoulder blades
Control System

Remote
Controlled.
Real-Time Data.

K9 Diesel's wireless remote controller is what separates it from passive canine training models. Instructors control every parameter of the patient — breathing, pulse, bleeding, sounds — and receive real-time feedback on student intervention accuracy without approaching the platform.

Long-Range Wireless Controller With Live Intervention Monitoring

The RC system is designed to be easy to learn — takes only minutes to master. LED indicators and LCD readouts immediately display critical vital and intervention data, giving instructors instant assessment of student performance without disrupting the scenario.

Push-button controls allow real-time modification of all key parameters mid-scenario — instructors can escalate or de-escalate patient status in direct response to trainee interventions, creating a genuinely reactive training environment.

The remote is easy to use and takes only minutes to learn — designed for operational personnel, not simulation technicians.
LCD Readout
Displays critical vital and intervention data in real time — pulse rate, breathing status, BP readings.
LED Indicators
Immediate visual feedback on effectiveness of student interventions — decompression, IO placement, airway.
Intubation Tooth Sensor
Sensor detects and registers contact with teeth during intubation — provides immediate training feedback on technique.
Real-Time Sensor Data
Monitor multiple intervention sites simultaneously — instructors see student performance data as it happens.
Push-Button Controls — Live Modification
Pulse Rate Adjustable in real time — increase or decrease mid-scenario
Pulse Strength Normal, bounding or thready — reflects patient status
Breathing Rate & Depth Active chest rise and fall — adjustable speed and depth
Bleeding Rate Control haemorrhage at junctional wound sites
Audio Mode Growling, barking, whimper, stertor, stridor — selectable
GDV & Tension Pneumothorax Toggle the GDV site and TP state on or off mid-scenario
Dead or Alive Set patient state to indicate CPR need or training outcome
Scenario Setup & Toggle Program breathing, pulse, bleeding, GDV and TP into reusable scenarios
Hemostatic Wounds With Pressure-Sensor Feedback

K9 Diesel's bilateral axillary wounds incorporate pressure-sensitive sensors that detect correct wound-packing technique — when sufficient pressure is applied, bleeding occludes and the RC signals success. Insufficient pressure keeps the wound bleeding. Trainees receive immediate, measured feedback on intervention quality.

Axillary Wounds
Pressure Sensor
CPR
Tension Pneumothorax
Work With TacMed

Ready To
Deploy
K9 Diesel?

K9 Diesel is a specialist platform — the right deployment depends on your handler training program, veterinary curriculum and whether you're integrating with existing simulation infrastructure.

Our team includes in-house Paramedics and Special Operations Medics who understand both the operational context and the training requirements of MWD handler programs. Start with a conversation.

No obligation. No hard sell. A conversation about your training program.

01
Define Your Program

Tell us about your K9 unit — working dog roles, casualty scenarios, operating environments and handler experience level. We'll identify which configuration fits your requirements and procurement pathway.

02
Configure & Integrate

K9 Diesel works alongside your human casualty simulators and environmental platforms. We'll spec the right wound patterns and RC setup, and integrate K9 Diesel into your broader simulation program.

03
Sustained Support

Consumables, maintenance guidance, scenario development and operator training as your K9 medical program matures. TacMed's after-sale support keeps your simulator investment operational.